G40 Patient Monitor

G40 Patient Monitor


Product Description

  • 12.1″color TFT display
  • Maximum 8 waveforms display
  •  7-lead ECG simultaneous display
  • ST and arrhythmia analysis
  • Optional dual-channel IBP and CO2 monitoring
  • Drug dose calculation and titration table
  • OxyCRG dynamic view display
  • Applications from neonate to adult
  • LAN networking capability to UT4800 Central Monitoring System
  • External VGA interface

Additional Information

ECG

Lead type: Standard 3-Lead or 5-Lead selectable
Lead selection: I, II, III, or I, II, III, aVR, aVL, aVF, V
HR measurement range: 15 bpm – 300 bpm
Accuracy: ±5 bpm or ±1% whichever is greater
Arrhythmia: 13 calls
ST measurement range: -0.8 mV – +0.8 mV
Accuracy: ±0.02 mV or ±5%
Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Gain selection: x 1/4, x 1/2, x 1, x 2, x 4, Auto
Pacemaker detection: Yes
Protection: Against electrosurgical interference
and defibrillation

SpO2

Philips SpO2 Technology
Measurement range: 0 – 100%
Accuracy: 70% – 100%, depends on sensor
0 – 69%, unspecified
PR range: 30 bpm – 240 bpm
PR accuracy: ±2 bpm or ±2%, whichever is greater

Non Invasive Blood Pressure (NIBP)

Method: Automatic oscillometric
Parameters: SYS/DIA/MAP/Pulse Rate
Operating modes: Manual/Auto/STAT
Auto measure time: 1 – 10, 15, 30, 60, 90, 120, 180, 240, 480 minute intervals
Units: mmHg/kPa
Cuff pressure range: Adult/Pediatric 0 – 300 mmHg
Neonate 0 – 150 mmHg
Measurement and alarm range:
SYS:
Adult 30 mmHg – 254 mmHg (4kPa – 33.9kPa)
Neonate 30 mmHg – 135 mmHg (4kPa – 18kPa)
DIA:
Adult 10 mmHg – 220 mmHg (1.3kPa – 29.3kPa)
Neonate 10 mmHg – 110 mmHg (1.3kPa – 14.7kPa)
Accuracy: Max. Std. Deviation: 8 mmHg (1.1kPa)
Max. Mean Error: ±5 mmHg (±0.7kPa)
Over-pressure protection: Yes

Respiration (RESP)

Measurement method: Thoracic impedance
RESP measurement and alarm range: 0 rpm – 120 rpm
Measurement accuracy: ±2 rpm
Waveform speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Gain selection: x 1/2, x 1, x 2
Lead connection: RA-LA, RA-LL, LA-RL, LL-RL
Apnea alarm: Yes, 5 – 120s

Temperature (TEMP Probe Is Optional)

Range: 0 – 50°C (32 – 122°F)
Resolution: 0.1°C (0.2°F)
Accuracy: ±0.1°C (±0.2°F)
Channel: 2 channels
Units: °C/°F

EtCO2 (optional)

Method: Microstream, Infrared Absorption
Parameters: awRR, EtCO2, InCO2 Measurement range: 0 – 99 mmHg (0kPa – 13.2kPa)
Accuracy: 0 – 38 mmHg: ±2 mmHg (0kPa – 5.1kPa ±0.28kPa)
39 – 99 mmHg: ±5% of reading + 0.08% for every
1 mmHg above 38 mmHg (5.2 – 13.2kPa: ±5% of
reading + 0.08% for every 0.13kPa above 5.1kPa)
Resolution: 1 mmHg (0.13kPa)
Display sweep speeds: 6.25 mm/s, 12.5 mm/s, 25 mm/s
Respiration rate: 0 – 150 breaths/min
Respiration accuracy: ±1 rpm in the range of 3 – 70 rpm
±2 rpm in the range of 71 – 120 rpm
±3 rpm in the range of 121 – 150 rpm
Units: mmHg/kPa

IBP (optional)

Channel: 2 channels
Parameters: SYS/DIA/MAP/Pulse Rate
Measurement range: -50 – 400 mmHg (-6.6kPa – 53.2kPa)
Accuracy: ±4% of reading or ±4 mmHg (0.53kPa),
whichever is greater
Resolution: 1 mmHg (0.13kPa)
Units: mmHg/kPa
Transducer sensitivity: 5uV/V/mmHg

Recorder (optional)

Type: Built-in thermal recorder, 3 channels
Print mode: Waveform and text

Display

Type: Color TFT LCD
Size: 12.1″ (30.73cm)
Resolution: 800H x 600V Pixels
Channels: 6 channels or 8 channels (adjustable)

Power Supply

Battery: Detachable battery (1standard, 2nd battery optional)
Maximum 1 hour continuous monitoring (1 battery)
Maximum 2 hours continuous monitoring (2 batteries)
AC power requirements: 100 – 240VAC, 50/60Hz

Safety Approval & Quality System

Safety standard: IEC60601-1
Quality system: ISO9001 & IS013485 certified

Weight & Dimensions

Net weight: Approx. 5.5kg
Dimensions: 318 mm (w) x 156 mm (d) x 328 mm (h)

Parameters

Standard: ECG, HR, RESP, NIBP, SpO2, PR, 2 x TEMP
Optional: 2 x lBP, EtCO2

Data Review And Storage

600 sets NIBP including all parameters at time of measurement
200 alarm events
120-hour trend graph of all parameters
12-minute full disclosure ECG waveform review

Data Output

ECG analog output, VGA output

Languages

Chinese, English, French, Italian, Polish, Russian, Turkish, Spanish,
Portuguese, German, Dutch, Swedish, Romanian, Danish, Norwegian

Reviews

There are no reviews yet.

Be the first to review “G40 Patient Monitor”